Guide

Water Softener Programming Guide

Programming a softener is a two-part job: first getting into the settings menu, then entering the right values. This guide covers common Fleck, Clack WS1, GE, and Whirlpool control types, then explains the Fleck SXT parameters. The reference is for understanding a single-tank downflow installation, not a universal replacement for its system supplier’s settings.

How to access the settings menu on your model

Different controllers reach their settings differently — digital Fleck and Clack valves use button combinations, while mechanical valves use physical dials and GE/Whirlpool units step through a front-panel menu. Find your model below.

Fleck SXT digital controllers

Fleck 5600SXT; consult the matching manual for other SXT valves

  1. Confirm the valve is in service. For the 5600SXT downflow manual linked below, first set the time display to 12:01 PM and press Extra Cycle to exit clock setting.
  2. Hold Up (▲) and Down (▼) together until the Display Format screen appears. At a normal clock time, the same combination opens User Programming instead.
  3. Press the Extra Cycle button (the circular-arrow / regen key) to advance from one parameter to the next.
  4. Use the Up/Down arrows to change the flashing value.
  5. Step past the last parameter with Extra Cycle to save and return to the normal time display.

To set the 5600SXT clock, hold either arrow until TD appears, adjust the time, and press Extra Cycle. Restore the actual clock after Master Programming. Confirm the procedure against your firmware manual.

Fleck mechanical time-clock valves

Fleck 5600 and 2510 mechanical controllers

  1. There is no digital menu — settings are physical dials under the valve cover.
  2. Set the time of day by rotating the large gear until the current time lines up with the time-of-day pointer.
  3. Set regeneration days on the skipper / program wheel by pushing the pins in (or out) for the days you want it to regenerate.
  4. Cycle times are set by the cam and micro-switches — usually left at the factory presets for residential use.
  5. To regenerate now, turn the manual regeneration knob to the regen position.

Mechanical time-clock and metered versions have different dials and procedures. Twin-alternating 9000/9100 systems need their own controller instructions; the calculator does not program them.

Clack WS1

Clack WS1

  1. From the normal time display, press NEXT and the Down (▼) button together for 3 seconds and release.
  2. Press NEXT and Down (▼) together again for 3 seconds to enter Master Programming.
  3. Use NEXT to advance and REGEN to step back through the settings.
  4. Use the Up/Down arrows to change each value.
  5. Press NEXT past the final screen to save and exit.

If the second screen doesn't appear within ~5 seconds the valve is locked: press ▼, NEXT, ▲, SET CLOCK in sequence, then retry. Set the clock separately with the SET CLOCK button (hours, then minutes).

GE softeners

GE GXSH40V

  1. Press the SET / SELECT (menu) button on the front panel to begin stepping through the settings.
  2. The display advances through time of day, water hardness, and recharge (regeneration) time.
  3. Use the Up/Down arrows to change the flashing value, then press SET / SELECT to confirm and move on.
  4. Finish the sequence to return to the normal display.
  5. To recharge immediately, press and hold the Recharge button for ~3 seconds.

GE softeners auto-sense and often only need the hardness and time set. The exact button labels vary by panel revision.

Whirlpool softeners

Whirlpool WHES40

  1. Press the PROGRAM button to display the flashing time of day; set it with the Up/Down buttons.
  2. Press PROGRAM again for water hardness (in grains); set it with Up/Down — add ~5 per 1 PPM of iron.
  3. Press PROGRAM again for recharge time (default 2:00 AM) and adjust if needed.
  4. Press PROGRAM again to choose salt type (NaCl or KCl), then PROGRAM once more to exit.
  5. To recharge now, press and hold the RECHARGE button for ~3 seconds until it flashes.

Use the WHES40 manual for this sequence. Similar-looking GE, Whirlpool, and EcoPure panels can have different menus and model-specific settings.

Want the full sequence for your valve, step by step? See the detailed walkthroughs for the Fleck 5600SXT, the Clack WS1, and GE and Whirlpool softeners.

Parameter reference

Capacity must match the salt dose and installed resin, while hardness comes from a water test and reserve from the allowance you choose for the regeneration delay. The calculator keeps that capacity–dose pair together, subtracts the selected reserve once, and only estimates brine refill after you confirm the BLFC. Its 5600SXT reference leaves valve configuration, cycle times, and day override with your installer’s instructions and asks for the actual meter type.

CodeSettingValue / actionWhat it does
DFDisplay FormatConfirm unitsUse the units configured for your system; Gal is the gallons option.
VTValve TypeKeep installer settingThe valve body and regeneration direction determine this setting.
CTControl TypeKeep installer settingFd is meter-delayed operation; do not change the control mode just to match an example.
NTNumber of TanksConfirm installationThe calculator reference is only for a single-tank metered downflow installation.
CUnit CapacityMatched operating capacityUse capacity at the selected salt dose, expressed in the units your display expects. A marketing grain rating is not a universal operating setting.
HHardnessTested / compensated GPGUse measured hardness with the compensation required for the water and system.
RSReserve SelectionConfirm reserve methodrc uses a fixed gallon reserve; SF uses a percentage. Do not apply both methods to the same allowance.
RCReserve CapacitySelected reserve gallonsAllow for water needed before scheduled regeneration. The 5600SXT limits fixed reserve to half its calculated gallon capacity.
DODays OverrideKeep installer settingA separate maximum time between regenerations, not the predicted capacity interval or a universal 3–14-day rule.
RTRegeneration TimeLow-use hourChoose an appropriate time for the household and confirm the clock.
BWBackwashKeep installer settingDepends on the resin bed, flow control, and installation.
BDBrine Draw + Slow RinseKeep installer settingDepends on the injector, brine draw, and system instructions.
RRRapid RinseKeep installer settingRetain the system-specific rinse duration.
BFBrine FillConfirm BLFCEstimate from salt dose and the installed brine-line flow control; do not use a fixed minutes-per-cubic-foot rule.
FMFlow MeterConfirm installed metert0.7 means a ¾-inch turbine; P0.7 means a ¾-inch paddle wheel. Choose the actual meter, not a guessed default.

Manufacturer references

Use the Pentair 5600SXT downflow manual for clock and programming access, reserve limits, and meter codes. The Whirlpool WHES40/WHES44 manual provides the WHES40 programming sequence and its capacity–salt-dose ratings. Match the model and revision on your own softener before making changes.

Before you change anything

Write down your valve’s current values first, so you can restore them if needed. Follow the matching manual’s regeneration procedure, observe draw and refill, check for leaks, and test outlet hardness. Draw and refill alone do not establish that the salt dose or operating capacity is correct.

After programming

Programming is a one-time job, but the softener still needs routine care to keep performing. See the maintenance schedule for what to check weekly, monthly, and yearly, and the troubleshooting guide if something isn't working as expected.